Product Description
This Lowara 0.55kW single-phase, two-wire motor replaces the motor on a compatible 4-inch submersible bore pump. It is supplied as a motor only; the pump end is separate.
Replacement compatibility
Lowara pump models using a 0.55kW motor:
Links open PumpsWA’s complete pump packages for reference. The linked single-phase packages are three-wire versions; this two-wire motor uses a different starting arrangement.
The NEMA-standard shaft and mounting dimensions suit correctly matched bore-pump ends. Match the coupling and mounting arrangement, rotation, and the pump’s maximum shaft-power requirement over its intended operating range. A larger motor does not by itself increase the pump’s flow or pressure.
- Axial thrust capacity: 3000N.
Starting and controls
The starting capacitor and motor protection are built into this two-wire version, so a separate capacitor starter box is not required. Changing from a three-wire motor also changes the starting arrangement; the existing controls must suit the replacement.
Automatic pressure or level switching is a separate control function. Select the supply cable and protection to suit the motor nameplate and installation.
Construction
- Oil-filled motor with a rewindable stator.
- Stainless-steel outer sleeve.
- Mechanical seal protected by a sand guard.
- Motor lead with a removable watertight connector.
- Enclosure protection: IP68.
- Insulation: Class F.
Cooling and installation
- Maximum standard water temperature: 35°C with adequate cooling.
- Minimum cooling-water speed past the motor: 0.08m/s.
- Maximum submergence: 150m below the water surface.
- Water pH: 4–8.
- Maximum starts with direct starting: 30 per hour, evenly spaced.
Water must flow around the motor casing to remove heat. Fit a cooling sleeve where the installation cannot provide the required cooling flow. Keep the motor submerged and clear of sediment; do not run dry. Support the assembly with suitable installation hardware and never by the electrical cable. Extend the motor lead with correctly sized submersible cable and a waterproof joint.
The installation position must suit both the motor and the attached pump. Follow the instructions supplied with each.
Variable-speed operation
Confirm the exact motor version and controller compatibility before using a variable-speed drive. The two-wire starting arrangement must be specifically supported by the motor and drive instructions.